View Issue Details
ID | Project | Category | View Status | Date Submitted | Last Update |
---|---|---|---|---|---|
0000282 | JVT JM H.264/AVC reference software | encoder and decoder | public | 2011-10-28 17:10 | 2011-10-28 17:11 |
Reporter | Karsten Suehring | Assigned To | Karsten Suehring | ||
Priority | normal | Severity | minor | Reproducibility | always |
Status | resolved | Resolution | fixed | ||
Product Version | JM-17.0 | ||||
Target Version | JM 18.1 | Fixed in Version | JM 18.1 | ||
Summary | 0000282: Temporal direct mode does not take field parity into account | ||||
Description | Accessing a reference frame from a field when mapping colocated ref_idx can select the wrong field parity reference. | ||||
Steps To Reproduce | HHI test suite rplr04 | ||||
Additional Information | works with JM 16.2 | ||||
Tags | No tags attached. | ||||
Date Modified | Username | Field | Change |
---|---|---|---|
2011-10-28 17:10 | Karsten Suehring | New Issue | |
2011-10-28 17:10 | Karsten Suehring | Status | new => assigned |
2011-10-28 17:10 | Karsten Suehring | Assigned To | => Karsten Suehring |
2011-10-28 17:11 | Karsten Suehring | Note Added: 0000511 | |
2011-10-28 17:11 | Karsten Suehring | Status | assigned => resolved |
2011-10-28 17:11 | Karsten Suehring | Fixed in Version | => JM 18.1 |
2011-10-28 17:11 | Karsten Suehring | Resolution | open => fixed |