View Issue Details

IDProjectCategoryView StatusLast Update
0000233JVT JM H.264/AVC reference softwareencoderpublic2011-11-10 16:35
ReporterDavid Fernando Suarez Diaz Assigned ToKarsten Suehring  
PrioritynormalSeverityminorReproducibilityalways
Status closedResolutionduplicate 
Product VersionJM 17.1 
Summary0000233: MVCEnableInterViewFlag ???
DescriptionI tried to use the MVC Stereo High Profile (118) to do some tests. I would like to see how the encoding process changes according to the value of this flag, however when I imposed it to 1 or 0 (enabled or disabled) the reference list prediction is the same. Is that correct?? Isn't supposed that it should be different?? For example, if I'm coding 2 views, precisely a frame from the second view, and the NumberReferenceFrames = 2, the encoder doesn't use a frame from the first view to do the prediction, instead use two reference frames always from view_id = 1 (second view).
TagsNo tags attached.

Relationships

duplicate of 0000266 resolvedKarsten Suehring that have 2 error in jm18.0 

Activities

Karsten Suehring

2011-11-10 16:35

administrator   ~0000515

Citing Alexis' comment from issues 0000266:

Set MVCInterViewReorder to 1. Otherwise your interview reference is placed at the end of the list, and thus not used.

Issue History

Date Modified Username Field Change
2010-09-10 11:30 David Fernando Suarez Diaz New Issue
2011-11-10 16:34 Karsten Suehring Relationship added duplicate of 0000266
2011-11-10 16:35 Karsten Suehring Note Added: 0000515
2011-11-10 16:35 Karsten Suehring Status new => closed
2011-11-10 16:35 Karsten Suehring Assigned To => Karsten Suehring
2011-11-10 16:35 Karsten Suehring Resolution open => duplicate