View Issue Details

IDProjectCategoryView StatusLast Update
0000084JVT JM H.264/AVC reference softwareencoderpublic2008-05-08 11:51
ReporterLitBird Assigned ToKarsten Suehring  
PrioritynormalSeverityminorReproducibilityalways
Status resolvedResolutionfixed 
Product VersionJM 13.0 
Fixed in VersionJM-14.1 
Summary0000084: invalid direction mode when BSliceSearch8x8=0
DescriptionWhen the option BSliceSearch8x8 is set to 0, JM 13.0 cannot finish encoding correctly. It always has the error message "invalid direction mode". I do not know why you have the error message, so it might be a bad way to disable the message. My setting file is attached. Thank you for your help.
TagsNo tags attached.

Activities

2007-11-27 08:49

 

N_B_130.cfg (9,380 bytes)

Karsten Suehring

2008-05-08 11:51

administrator   ~0000184

Fixed a boundary condition which should prevent selection of an invalid direct prediction mode.

Issue History

Date Modified Username Field Change
2007-11-27 08:49 LitBird New Issue
2007-11-27 08:49 LitBird File Added: N_B_130.cfg
2008-05-08 11:51 Karsten Suehring Status new => resolved
2008-05-08 11:51 Karsten Suehring Fixed in Version => JM-14.0-dev
2008-05-08 11:51 Karsten Suehring Resolution open => fixed
2008-05-08 11:51 Karsten Suehring Assigned To => Karsten Suehring
2008-05-08 11:51 Karsten Suehring Note Added: 0000184